POSITIP 8016 & POSITIP 8016 ACTIVE HEIDENHAIN
Axes
|
Up to 6 axes (4 axes in the standard version; 2 additional axes available as an option)
|
Encoder inputs
|
1 VPP, 11 µAPP, EnDat 2.2
|
Display step1)
|
Linear axis: 1 mm to 0.000 01 mm
|
Display
|
12-inch screen for touchscreen operation; resolution: 1280 x 800 pixels for position values, dialog messages, data input, and graphic functions
|
Functions
|
- Creation and execution of programs
- User administration and data management
- 100 presets, 100 tools
- Reference mark evaluation for distance-coded and single reference marks
- Distance-to-go mode with nominal position input in absolute or incremental values
- Graphic positioning aid
- Scaling factor, mirror image, magnifying function
|
For milling/drilling/boring
|
- Calculation of positions for hole patterns (bolt circles, linear hole patterns)
- Tool radius compensation
- Cutting data calculator
- Probing functions for preset acquisition (edge, centerline, and circle)
|
–
|
Control of up to 3 NC axes and a spindle; switching functions
|
For turning
|
- Measurement of tool dimensions
- Sum display of axes in the top slide
- Taper calculator
|
|
–
|
Control of up to 3 NC axes and a spindle; constant surface speed; switching functions
|
Error compensation
|
Linear and segmented linear
|
Data interface
|
2x Ethernet 100 Mbit / 1 Gbit (RJ45); 4x USB 2.0 (Type A)
|
Accessories
|
Single-Pos/Duo-Pos/Multi-Pos stands, Multi-Pos holder, power cable, adapter connector
|
Power connection
|
AC 100 V (–10 %) to 240 V (+5 %), 50 Hz to 60 Hz (±5 %)
PT 8016 Active: ≤ 79 W; PT 8016: ≤ 38 W
|
Operating temperature
|
0 °C to +45 °C (storage temperature: –20 °C to +70 °C)
|
Protection EN 60529
|
IP65, back panel IP40
|
Mounting
|
Single-Pos/Duo-Pos/Multi-Pos stands, Multi-Pos holder, and other mounting systems
with a 100 mm x 100 mm hole pattern
|
Mass
Device alone
Device with Single-Pos stand
Device with Duo-Pos stand
Device with Multi-Pos stand
Device with Multi-Pos holder
|
3.50 kg
3.60 kg
3.80 kg
4.50 kg
3.85 kg
|
1) Depends on the signal period or line count of the connected encoder
|
|